A New Temperature Control Mod for Mirages
Kees is now offering a needle valve assembly which can be installed in the thermosiphon loop on the Mirage. (If you're unfamiliar with how heat exchanger espresso machines work, here is a primer.) The adjustment screw allows the operator to easily control the water flow-rate between the boiler and the group head, thus controlling the extraction temperature at each group.
Kees offers basic parameters after the jump.
Kees offers basic parameters after the jump.
Adjusting the Mirage Needle-type Restrictors
General indications of temperature in Celsius in coffee bed:
-turned fully down 89
-one full turn upwards 92
-two full turns upwards 95
-three full turns upwards 97
-four full turns upwards 98
-five full turns upwards 99
-fully upwards 100
Disclaimer
General indications of temperature in Celsius in coffee bed:
-turned fully down 89
-one full turn upwards 92
-two full turns upwards 95
-three full turns upwards 97
-four full turns upwards 98
-five full turns upwards 99
-fully upwards 100
Disclaimer
- Please note these are approximate indications only.
- The temperature measured inside the coffee bed also depends on the rate of the extraction flow (faster flow results in a higher reading, slower in a lower reading).
- The above results were found with the pressurestat adjusted to 1.3-1.4 bar, water level inside main boiler at standard level, shots of 60cc (2 ounces) in 25 seconds, machine body fully closed, short flush of 20cc before every shot, 45 seconds between shots.




Erin Nov 24, 2008 – 3:36 PM
This is amazing! No more late night restrictor change-outs for Tomas! I need a shirt that sez "I Heart Kees".